Project Manager-Bulk Edit

The Bulk Edit dialog in Project Manager provides global modification options tailored to specific entity types. The modifications selected within will be applied to all selected entities within Project manager.

Bulk edit options

Entity

Bulk Edit Options

Functionality

Drawing

Not available

 

Schedule

Not available

 

Object

Label

Object labels are not required to be unique. This option allows you to apply a consistent label to all selected objects.

Description

Object descriptions are not required to be unique. This option allows you to apply a consistent description to all selected objects.

Status

Options - Enabled or Disabled. Disabling an object makes it invisible and it will not participate in calculations.

Lock

Options - Locked or Unlocked. Locking an object makes it not modifiable - the object is visible and participates in the calculations but it cannot be edited, moved, deleted, etc, unless the object is unlocked.

Wireframe Color

Apply a consistent wireframe color to all selected objects.

Labeling

This option allows you to add consistent  Object Labeling options (Object, Component and Component Surface) to all selected objects.

A Labeling Flag is shown if Labels are applied (3 digit number, each number indicates an option in the correlated Object Labeling tab)

Room

Label

Room labels are not required to be unique. This option allows you to apply a consistent label to all selected rooms.

Description

Room descriptions are not required to be unique. This option allows you to apply a consistent description to all selected rooms.

Off

Options - On or Off. Turning a room off makes it invisible.

Lock

Options - Locked or Unlocked. Locking a room makes it not modifiable - the room is visible and participates in the calculations but it cannot be edited, moved, deleted, etc, unless the room is unlocked.

Color

Apply a consistent wireframe color to all selected rooms.

Labeling

This option allows you to add consistent Room Labeling options (Room and Room Surface) to all selected rooms.

A Labeling Flag is shown if Labels are applied (3 digit number, each number indicates an option in the correlated Room Labeling tab).

CalcPts

Not available

 

Luminaire

Label

Replace the current luminaire "types" with an alternate from a selection of defined luminaires.

Status

Options - Enabled or Disabled. When Disabled, luminaires are invisible and do not participate in the lighting calculations.

Locked Status

Options - Locked or Unlocked. Locking a luminaire makes it not modifiable - the luminaire is visible and participates in the calculations but it cannot be edited, moved, deleted, etc, unless the luminaire is unlocked.

Channel

This option allows you to change the Channel of the selected luminaire(s).

Aiming Vector Visibility

Options - On or Off. This option allows you to control the visibility of Aiming Vectors for the selected luminaires. By default Aiming vectors are visible.

Only luminaires located with Locate and Aim have aiming vectors visible.

Template Visibility

Options - On or Off. This option allows you to control the visibility of Templates for the selected luminaires. By default Templates are visible.

Luminaire Templates must be defined to be displayed in Model Mode (i.e. both definition and visibility must be enabled to visualize templates in Model Mode).

Photometric Web Visibility

Options - On or Off. This option allows you to control the visibility of Photometric Webs for the selected luminaires. By default Photometric Webs are invisible.

Photometric Webs use the current Photometric Web Specifications when made visible.

Label Visibility

Options - On or Off. This option allows you to control the visibility of luminaire labels. By default labels are visible.

Luminaire Labels must be specified (e.g. ON and attributes defined) to be displayed in Model Mode (i.e. both specification and visibility must be enabled to visualize labels in Model Mode).

LPD/UWLR Area

Not available

 

Statistical Area

Not available